- Designed to handle water and debris of up to one inch and is used in agriculture, marine and construction.
- Keep away from electrical sources and other electrical equipment.
- Do not ever run the pump dry.
- Turn engine off when refueling.
- Do not pump water containing chemicals.
- Do not pump flammable materials.
- Do not ever run the pump dry.
- Turn engine off when refueling.
- Do not pump water containing chemicals.
- Do not pump flammable materials.
- Maximum capacity of 11,400 (US gallons per minute).
- 5.5 Hp Honda motor.
- Run time/tank (Hr) - 3.3.
- Maximum discharge head (ft) - 90.
- Weight 82 lbs.
- Dimensions (L x W x H in) 23 1/4 x 18 1/4 x 17 3/8.
- 5.5 Hp Honda motor.
- Run time/tank (Hr) - 3.3.
- Maximum discharge head (ft) - 90.
- Weight 82 lbs.
- Dimensions (L x W x H in) 23 1/4 x 18 1/4 x 17 3/8.
- Ensure that oil and gas are full by checking fuel levels.
- Connect intake and discharge hoses.
- Place discharge hose in an area where drainage of water is permissible.
- Prime pump with water.
- Start engine and adjust throttle according to requirements of job.
- Let it run until all the water has been pumped from the respective place.
- Once all the water has been pumped, stop the pump, detach the hose and drain excess water from the pump via the drain plug.
- For full operating instructions, please refer to the operators manual.
- Connect intake and discharge hoses.
- Place discharge hose in an area where drainage of water is permissible.
- Prime pump with water.
- Start engine and adjust throttle according to requirements of job.
- Let it run until all the water has been pumped from the respective place.
- Once all the water has been pumped, stop the pump, detach the hose and drain excess water from the pump via the drain plug.
- For full operating instructions, please refer to the operators manual.
Pump operates but does not pump water.
- There is an airlock within the pump.
- Something is obstructing the flow of water within the pump.
- Hose is kinked.
- Check oil and gas.
- The pump has not maintained its prime.
- Ensure intake hose screen is not covered with debris.
- Ensure rubber washers are in the hoses.
- There is an airlock within the pump.
- Something is obstructing the flow of water within the pump.
- Hose is kinked.
- Check oil and gas.
- The pump has not maintained its prime.
- Ensure intake hose screen is not covered with debris.
- Ensure rubber washers are in the hoses.